Current Position:Home>>Kits>>Metabolism Assays>> Proline (Pro) Colorimetric Assay Kit
Cat.No.:E-BC-K177-S
Welcome to order from local distributors.
Protocols for metabolism assays
Add to cart Bulk requestFor research use only. Order now, ship in 3 days
Synonyms | Pro |
Sample type | Plant tissue,honey |
Sensitivity | 0.17 μg/mL |
Detection range | 0.17-35 μg/mL |
Detection method | Colorimetric method |
Assay type | Quantitative |
Assay time | 80 min |
Precision | Average inter-assay CV: 5.400%Average intra-assay CV: 4.500% |
Other instruments required | Water bath, Micropipettor, Vortex mixer, Balance, Centrifuge |
Other reagents required | Acetic acid, Methylbenzene, Absolute ethyl alcohol |
Storage | 2-8℃ |
Valid period | 12 months |
The levels of proline concentration was significantly increased with salt tolerance and reversed by WR10. (**P<0.01 vs Control, ##P<0.01 vs NaCl)
ZH Yue et al investigate the function of Bacillus altitudinis for improving salt tolerance in wheat. Proline (Pro) level in wheat tissue was determined using Proline colorimetric assay kit (E-BC-K177-S).
It is recommended to take 2~3 samples with expected large difference to do pre-experiment before formal experiment and dilute the sample according to the result of the pre-experiment and the detection range (0.17-35 μg/mL).
The recommended dilution factor for different samples is as follows (for reference only):
Sample type |
Dilution factor |
Green pepper tissue homogenization |
1 |
Carrot tissue homogenization |
1 |
Epipremnum aureum tissue homogenization |
1 |
Lettuce leaf tissue homogenization |
1 |
Honey |
1 |
Cabbages tissue homogenization |
1 |
Note: The diluent is Reagent 1.
PMID: 35909740 |
Sample: shoot |
D*********aSubmitted [ Nov 28 2022 ]
Asked: as asked previously above, in your Application sheet you don\'t indicate the concentrations of methylbenzene and acetic acid preparations, which WE have to prepare, as they are not provided in the kit. Without knowing such concentrations, it is not posible to perform the assays. Culd you please provide the needed concentrations? Thank you.
Reply
adminSubmitted [ Nov 28 2022 ]
Answered: Dear Georgina, we will reply to you by email. Please pay attention to the mailbox
M**********dSubmitted [ Aug 18 2022 ]
Asked: Any other solvent can replace toluene?
Reply
adminSubmitted [ Aug 18 2022 ]
Answered:
D********dSubmitted [ Aug 02 2022 ]
Asked: Is it necessary to fit a standard curve for calculation?
Reply
adminSubmitted [ Aug 02 2022 ]
Answered: You don't have to. The linearity is good enough to calculated with a standard sample, and fitting a standard curve will take you a lot of time. But the situation only happens for this kit.
A***************iSubmitted [ Jan 09 2019 ]
Asked: Hi, I was wondering whether this kit is suitable for measuring proline in animal tissue or mammalian cells. Thanks Alessandro
Reply
adminSubmitted [ Jan 09 2019 ]
Answered: Dear Alessandro For this kit, we only tested on plant samples, for your samples, we advise to do a pre-test.
v*ySubmitted [ Oct 12 2018 ]
Asked: Hello, we have receive your Proline Assy Kit. We would likte to process a quantification but in your Application sheet you don\'t indicate the concentrations of methylbenzene and acetic acid preparations. Could you give me these concentrations work please? Thanks you.
Reply
adminSubmitted [ Oct 12 2018 ]
Answered: Hi Vey, The infrmation you need is confidential. May I know why do you need this information? Thank you. Best regards, Elabscience