Current Position:Home>>Kits>>Metabolism Assays>> Alanine Aminotransferase (ALT/GPT) Activity Assay Kit
Cat.No.:E-BC-K235-M
Welcome to order from local distributors.
Protocols for metabolism assays
Add to cart Bulk requestFor research use only. Order now, ship in 3 days
Synonyms | ALT,GPT,Glutamic-pyruvic transaminase |
Sample type | Serum,plasma,animal tissue,cells,cell culture supernatant |
Sensitivity | 0.75 IU/L |
Detection range | 0.75-72.3 IU/L |
Detection method | Colorimetric method |
Assay type | Enzyme Activity |
Assay time | 80 min |
Precision | Average inter-assay CV: 9%Average intra-assay CV: 5.300% |
Other instruments required | Micropipettor, Vortex mixer, Incubator, Multichannel pipette |
Other reagents required | Normal saline (0.9% NaCl), PBS (0.01 M, pH 7.4) |
Storage | 2-8℃ |
Valid period | 12 months |
No significant change of ALT activity was observed, the LCFG nanoparticles did not include hepatotoxicity.
X Zhang et al investigate the usage of H2O2 and O2 for cooperative chemodynamic/starvation cancer therapy. Alanine aminotransferase (ALT) avtivity in mouse blood was determined using ALT activity assay kit (E-BC-K235-M).
It is recommended to take 2~3 samples with expected large difference to do pre-experiment before formal experiment and dilute the sample according to the result of the pre-experiment and the detection range (0.75-72.3 IU/L).
The recommended dilution factor for different samples is as follows (for reference only):
Sample type |
Dilution factor |
Human serum |
1 |
Human plasma |
1 |
Porcine serum |
1 |
Rat serum |
1 |
10% Rat brain tissue homogenization |
1 |
10% Rat heart tissue homogenization |
1 |
10% Rat liver tissue homogenization |
40-60 |
10% Rat kidney tissue homogenization |
1 |
Note: The diluent is normal saline (0.9% NaCl) or PBS (0.01 M, pH 7.4).
PMID: 34681767 |
Sample: Serum |
Sample: Serum |
Sample: Serum |
PMID: 33727180 |
Sample: Serum |
Sample: Serum |
Sample: Plasma |
Sample: Serum |
DOI: 10.5650/jos.ess22033 |
|
PMID: 35965085 |
Sample: Liver |
DOI: 10.1002/ddr.21581 |
|
Sample: Liver |
PMID: 32705206 |
Sample: Serum |
DOI: 10.2131/jts.47.169 |
|
PMID: 35527005 |
Sample: Serum |
PMID: 34093755 |
Sample: Serum |
Sample: Serum |
Sample: Serum |
DOI: 10.1155/2022/7832540 |
|
Sample: Hepatic Tissue,Serum |
Sample: Serum |
DOI: 10.1042/BSR20171162 |
|
Sample: Plasma |
DOI: 10.7717/peerj.13082 |
|
PMID: 35310165 |
Sample: Plasma |
DOI: 10.1155/2021/7512957 |
|
Sample: Mandibular Bone |
PMID: 34871743 |
Sample: Serum |
Sample: Serum |
PMID: 31824338 |
Sample: Plasma |
PMID: 35010758 |
Sample: Plasma |
DOI: 10.1002/jbt.23177 |
|
PMID: 35983967 |
Sample: Serum |
PMID: 35298730 |
Sample: Serum |
PMID: 32035931 |
Sample: Whole Blood,Tissue Homogenate |
PMID: 35277165 |
Sample: Serum |
PMID: 35035768 |
Sample: Blood |
PMID: 34597886 |
Sample: Serum |
Sample: Blood |
PMID: 35443217 |
Sample: Serum |
DOI: 10.1039/D1DT00185J |
|
PMID: 33982702 |
Sample: Serum |
Sample: Blood |
DOI: 10.1111/jcmm.15614 |
|
PMID: 32678475 |
Sample: Serum |
DOI: 10.1111/jcmm.15498 |
|
Sample: Serum |
PMID: 33827384 |
Sample: Serum |
PMID: 34461274 |
Sample: Blood |
PMID: 34717194 |
Sample: Serum |
PMID: 35341826 |
Sample: Serum |
DOI: 10.3390/v13112213 |
|
PMID: 34835018 |
Sample: Serum |
Sample: Serum |
Sample: Serum |
PMID: 36230124 |
Sample: Serum |
Sample: Serum |
Sample: Serum |
PMID: 34483906 |
Sample: Liver |
DOI: 10.3390/ijms23105490 |
|
Sample: Serum |
DOI: 10.3390/ijms24010670 |
|
Sample: Aml-12 Cell |
DOI: 10.1002/ptr.7608 |
|
PMID: 36086852 |
Sample: Serum |
PMID: 36068769 |
Sample: Serum |
PMID: 34209524 |
Sample: Serum |
Sample: Serum |
PMID: 34591933 |
Sample: Serum |
PMID: 31356863 |
Sample: Serum |
Sample: Serum |
Sample: Serum |
PMID: 34571217 |
Sample: Liver Organoids (Los) |
PMID: 35588832 |
Sample: Serum |
PMID: 36058506 |
Sample: Serum |
PMID: 34757230 |
Sample: Serum |
Sample: Plasma |
PMID: 33360192 |
PMID: 34448397 |
Sample: Plasma |
PMID: 36103835 |
Sample: Serum |
PMID: 36090760 |
Sample: Plasma |
DOI: 10.1002/hep.29573 |
|
Sample: Serum |
PMID: 36808719 |
Sample: Serum |
PMID: 36572670 |
Sample: Serum |
Verified Customer
a****gSubmitted [ May 29 2019 ]
Y**NSubmitted [ Sep 22 2023 ]
Asked: Hi, I am using a kit from another company to measure ALT in HepG2. But I\'m worried because Normal is measured too high. Are there any cases where Normal is high when using this kit?
Reply
adminSubmitted [ Sep 22 2023 ]
Answered: Hi Yoon, This kit can detect HepG2 samples, and the following is a reference for laboratory result : ALT activity of HepG2:3.659U/gprot.
y**gSubmitted [ Aug 04 2023 ]
Asked: How to collect cell culture supernatant and perform subsequent detection experiments, and what is the difference between supernatant and direct use of cell lysis buffer?
Reply
adminSubmitted [ Aug 04 2023 ]
Answered: 1. The preparation of cell culture supernatant: Suspension cells: Centrifuge the cell suspension 1000g for 10 minutes, and take the supernatant on ice for detection. Adherent cells: directly absorb the supernatant, centrifuge 1000g for 10 minutes, and place on ice for detection. 2. The cell supernatant reflects the enzyme activity on the outside of the cell, while the cells treated with the cell lysis buffer reflect the enzyme activity inside the cell.
E**************zSubmitted [ May 15 2023 ]
Asked: We are currently using C57BL/6 strain and the maximum serum that we collect is only 30 uL. Can you tell me how much serum sample that I have to use for one experiment?
Reply
adminSubmitted [ May 15 2023 ]
Answered: The minimum requirement for a single well is 10 uL for kit E-BC-K235-M
M*****aSubmitted [ Aug 31 2022 ]
Asked: Will it affect result if this kit is at room temperature for half a month?
Reply
adminSubmitted [ Aug 31 2022 ]
Answered: No, it will not influence the result. Please ensure using.
M*****aSubmitted [ Aug 22 2022 ]
Asked: Can you please help me understand exactly what a carmen unit is and why we are using it instead of the conventional method of plotting a standard curve of concentration of standard vs the absorbance. How is the carmen unit relevant to this exact calculation I would also like to know how you arrived at the numbers 0, 28, 57, 97, 150, 200 for the standard Carmen values.
Reply
adminSubmitted [ Aug 22 2022 ]
Answered: 1. This indicator is special, and the method used is the Reitman-Frankel method. The standard curve of the Reitman-Frankel method is determined by comparing the colorimetric method experimental result with the result of karmen spectrophotometry (rate method), and the report result of Karmen units will be more accurate. 2. The Karmen's units corresponding to the standard are fixed and converted according to the concentration of pyruvate.