Current Position:Home>>Kits>>ELISA Kits>> Human Zonulin ELISA Kit
Cat.No.:E-EL-H5560
Welcome to order from local distributors.
Add to cart Bulk requestFor research use only. Order now, ship in 3 days
Assay type | Sandwich-ELISA |
Format | 96T/48T/24 |
Assay time | 3.5h |
Detection range | 0.78-50 ng/mL |
Sensitivity | 0.47 ng/mL |
Sample type &Sample volume | serum, plasma and other biological fluids; 100μL |
Specificity | This kit recognizes Human Zonulin in samples. No significant cross-reactivity or interference between Human Zonulin and analogues was observed. |
Reproducibility | Both intra-CV and inter-CV are < 10%. |
Application | This ELISA kit applies to the in vitro quantitative determination of Human Zonulin concentrations in serum, plasma and other biological fluids. |
Item | Specifications | Storage |
---|---|---|
Micro ELISA Plate(Dismountable) | 96T: 8 wells ×12 strips
48T: 8 wells ×6 strips |
-20℃, 12 months |
Reference Standard | 96T: 2 vials
48T: 1 vial |
|
Concentrated Biotinylated Detection Ab (100×) | 96T: 1 vial, 120 μL
48T: 1 vial, 60 μL |
|
Concentrated HRP Conjugate (100×) | 96T: 1 vial, 120 μL
48T: 1 vial, 60 μL |
-20℃(Protect from light), 12 months |
Reference Standard & Sample Diluent | 1 vial, 20 mL | 2-8°C, 12 months |
Biotinylated Detection Ab Diluent | 1 vial, 14 mL | |
HRP Conjugate Diluent | 1 vial, 14 mL | |
Concentrated Wash Buffer (25×) | 1 vial, 30 mL | |
Substrate Reagent | 1 vial, 10 mL | 2-8℃(Protect from light) |
Stop Solution | 1 vial, 10 mL | 2-8°C |
Plate Sealer | 5 pieces | |
Manual | 1 copy | |
Certificate of Analysis | 1 copy |
Intra-assay Precision (Precision within an assay): 3 samples with low, mid range and high level Human Zonulin were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, mid range and high level Human Zonulin were tested on 3 different plates, 20 replicates in each plate.
Intra-assay Precision | Inter-assay Precision | |||||
---|---|---|---|---|---|---|
Sample | 1 | 2 | 3 | 1 | 2 | 3 |
n | 20 | 20 | 20 | 20 | 20 | 20 |
Mean (ng/mL) | 2.46 | 5.57 | 22.64 | 2.31 | 6.06 | 23.45 |
Standard deviation | 0.14 | 0.27 | 1.23 | 0.12 | 0.28 | 1.02 |
CV (%) | 5.69 | 4.85 | 5.43 | 5.19 | 4.62 | 4.35 |
The recovery of Human Zonulin spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.
Sample Type | Range (%) | Average Recovery (%) |
---|---|---|
Serum(n=8) | 91-103 | 95 |
EDTA plasma (n=8) | 87-99 | 91 |
Cell culture media (n=8) | 91-99 | 95 |
Samples were spiked with high concentrations of Human Zonulin and diluted with Reference Standard & Sample Diluent to produce samples with values within the range of the assay.
Database Links | SwissProt:
P00738
|
Research Area | Cancer, Cardiovascular |
1. Add 100μL standard or sample to the wells. Incubate for 90 min at 37°C |
|
2. Discard the liquid, immediately add 100μL Biotinylated Detection Ab working solution to each well. Incubate for 60 min at 37°C |
|
3. Aspirate and wash the plate for 3 times |
|
4. Add 100μL HRP conjugate working solution. Incubate for 30 min at 37°C. Aspirate and wash the plate for 5 times |
|
5. Add 90μL Substrate Reagent. Incubate for 15 min at 37°C |
|
6. Add 50μL Stop Solution |
|
7. Read the plate at 450nm immediately. Calculation of the results |
DOI: 10.3390/biom9010024 |
|
PMID: 30641999 |
Sample: Plasma |
Sample: Plasma |
DOI: 10.3390/ijms23179814 |
|
PMID: 36077228 |
Sample: Serum |
Sample: Serum |
DOI: 10.3390/ijms22052453 |
|
PMID: 33671071 |
Sample: Plasma |
DOI: 10.1002/jgh3.12644 |
|
Sample: Blood |
Sample: Serum |
PMID: 33228404 |
Sample: Serum |
DOI: 10.4314/ahs.v21i3.26 |
|
Sample: Plasma |
Sample: Serum |
PMID: 31990165 |
Sample: Serum |
PMID: 32188439 |
Sample: Serum |
DOI: 10.1111/jpc.16033 |
|
Sample: Serum |
PMID: 32757874 |
Sample: Serum |
Sample: Serum |
DOI: 10.1111/jocd.15095 |
|
PMID: 35579378 |
Sample: Serum |
PMID: 35232303 |
Sample: Serum |
DOI: 10.1111/hiv.13059 |
|
PMID: 33426758 |
Sample: Serum |
PMID: 32989570 |
Sample: Serum |
Sample: Serum |
Sample: Serum |
PMID: 34988901 |
Sample: Serum |
Sample: Serum |
PMID: 32385356 |
Sample: Serum |
Sample: Serum |
PMID: 35212669 |
Sample: Plasma |
PMID: 34092777 |
Sample: Serum |
DOI: 10.3390/nu12061736 |
|
Sample: Plasma |
DOI: 10.1155/2020/8630275 |
|
PMID: 32089785 |
Sample: Serum |
DOI: 10.3390/nu13020363 |
|
PMID: 33504116 |
Sample: Serum |
DOI: 10.3390/nu14102153 |
|
PMID: 35631294 |
Sample: Serum |
Sample: Serum |
DOI: 10.3390/nu15010145 |
|
Sample: Serum |
Sample: Serum |
PMID: 33845254 |
Sample: Cell |
Sample: Serum |
DOI: 10.1002/hep.31056 |
|
PMID: 31808577 |
Sample: Serum |
A************iSubmitted [ Jul 27 2024 ]
Asked: \"Different target proteins are detected, and the sample content is different. It is recommended that you do a pre-test according to the original solution and dilute 5 times to confirm the concentration of the target protein in the feces samples.\" How much of the diluent should I use each time? Should I use PBS or specimen diluent?
Reply
adminSubmitted [ Jul 27 2024 ]
Answered: You can dilute the sample using the Reference Standard & Sample Diluent in the kit. When the sample is not diluted, it is not necessary to use standard product & sample diluent for sample loading. Sample dilution of 5 times requires at least 20ul sample +80ul standard & sample diluent. The loading volume of the sample is 100ul.
A************iSubmitted [ Jul 16 2024 ]
Asked: HI, when we a preparing the samples to the procedure using feces samples the supernates need to be diluted before starting the protocol of the kit?
Reply
adminSubmitted [ Jul 16 2024 ]
Answered: Different target proteins are detected, and the sample content is different. It is recommended that you do a pre-test according to the original solution and dilute 5 times to confirm the concentration of the target protein in the feces samples.
A************iSubmitted [ Jan 25 2024 ]
Asked: Hello, can I use this test on stool samples?
Reply
adminSubmitted [ Jan 25 2024 ]
Answered: Yes, this ELISA kit can be used to test feces samples.
H**********aSubmitted [ Dec 13 2023 ]
Asked: Hii, i want to know the range of zonulin levels that we will consider as normal and above which we will consider that the zonulin levels are elevated. Thank you.
Reply
adminSubmitted [ Dec 13 2023 ]
Answered: For E-EL-H5560 kit, the reference value of normal human serum samples is 40-115ng/ml, according to our internal verification result. However, considering about the individual differences, we recommend that you set up your own normal sample group as control in order to determine whether the zonulin levels are elevated.
S*eSubmitted [ Sep 13 2022 ]
Asked: In your previous answers to other questions, you said, \"the immunogen sequences of the capture antibody and detection antibody were human haptoglobin 19-406aa (#P00738).\" So that would mean that haptoglobin could produce a false positive or falsely elevated \"zonulin\" result in your test. How do you know you are detecting zonulin/pre-HB2 and not haptoglobin? You also said, \"The antigen is full-length recombinant pre-HP2. The expression host of the antigen is HEK 293 cell.\" Which antigen are you referring to in that second statement, since you already stated that the antigen which the capture antibody is specific for is haptoglobin rather than zonulin/pre-HP2? If the capture and detection antibodies react with both haptoglobin and pre-HP2, how is your assay specific for only pre-HP2? Thank you.
Reply
adminSubmitted [ Sep 13 2022 ]
Answered: We applied anti-ZOT antibodies in this kit, ZOT is an enterotoxin elaborated by Vibrio cholera, a zonulin analogue. It has been reported that this antibody specifically recognizes the human zonulin (pre-HP2) instead of the mature Haptoglobin. In addition, we verified that the kit does not have significant cross-reactivity with mature HP protein.
p***aSubmitted [ Mar 22 2022 ]
Asked: Good morning, We were thinking of purchasing this kit for an internal study regarding intestinal permeability. We were wondering if you could provide with information regarding the validity of this kit and the accuracy in detecting the pre-haptoglobin-2. Would appreciate quick reply! Thank you for your time and help!
Reply
adminSubmitted [ Mar 22 2022 ]
Answered: The zonulin protein is the inactive precursor for HP2 and it is an uncleaved single-chain form. For our kit, it can detect the Precursor of haptoglobin 2, the immunogen sequences of the capture antibody and detection antibody were human haptoglobin 19-406aa (#P00738). The sensitivity report will be shared via email.
h****nSubmitted [ Mar 15 2022 ]
Asked: Hi, I am wondering about the information on the variability of zonulin assay? And what are zonulin and occludin coefficients of variation? of other indexes of test-retest reliability?
Reply
adminSubmitted [ Mar 15 2022 ]
Answered: Hi Hicran, thanks for your message. For your question, not only zonulin or occludin kits, but all of our kits need to strictly check the precision evaluation parameters before shipment, that is, the intra-assay and inter-assay coefficients of variation of the kits are both <10%. Please refer to the manuals to obtain the coefficient of variation information of each kit. Thank you.
T***mSubmitted [ Dec 10 2021 ]
Asked: Does your kit not recognize complement C3, as it was said, \"Top matches of the assays\' detected antigen included haptoglobin and complement C3 for the assay manufactured by CUSABIO (Wuhan, China) and complement C3 for the assay manufactured by Immundiagnostik AG (Bensheim, Germany) after the nature of the assays\' detected antigen was investigated using immunoprecipitation followed by mass spectrometric analysis and sodium dodecyl sulphate-polyacrylamide gel electrophoresis (SDS-PAGE) followed by protein staining. (Ajamian et al., PloS One, 2019)
Reply
adminSubmitted [ Dec 10 2021 ]
Answered: Thanks for your message. E-EL-H5560 Human Zonulin ELISA Kit Yes, the kit can recognize zonulin, but cannot recognize complement C3. We also found the document you mentioned in the attachment, these words don't mean one kit can recognize two proteins (zonulin, complement C3), which means the CUSABIO kit can detect serum zonulin levels, and our understanding literature says is human complement C3c, HP1-1, HP2-2 and recombinant zonulin (zon) standards were separated by SDS-PAGE and stained with Coomassie gel stain . If you want to test for C3, we recommend E-EL-H6054 Human C3(Complement Component 3) ELISA Kit for you. https://www.elabscience.com/p-human_c3_complement_component_3_elisa_kit-356179.html
M*************iSubmitted [ Sep 09 2021 ]
Asked: Sorry for disturbing you again, I inquired few minutes ago about the reactivity of antibody to zonulin-recombinant. The another question is about What is the antigen when you make anti-zonulin antibody. I would appreciate your immediate attention to this matter.
Reply
adminSubmitted [ Sep 09 2021 ]
Answered: Dear Hayashi san,thanks for your message. This kit is specifically designed to detect Zonulin. The kit can be used to detect natural Zonulin. In theory, the kit also can be used for recombinant Zonulin. However, due to the influence of the immunogen sequence and the expression host of the recombinant protein, some recombinant Zonulin may not match the antibodies in the kit. Therefore, a pre-test is recommended. The antigen is full-length recombinant pre-HP2. The expression host of the antigen is HEK 293 cell. Best Regards, Y
H*************oSubmitted [ Sep 09 2021 ]
Asked: Recently some ELISA kits for zonulin are in controversy because they actually don\'t detect zonulin. I would like to know that you confirm antibodies used in your kits capture zonulin-recombinants because I would like to purchase reliable products. Thank you.
Reply
adminSubmitted [ Sep 09 2021 ]
Answered: Dear Hayashi san,thanks for your message. We have replied to you in your second message column, please check it out, thank you! Best regards,