Current Position:Home>>Kits>>Metabolism Assays>> Total Oxidant Status (TOS) Colorimetric Assay Kit
Cat.No.:E-BC-K802-M
Welcome to order from local distributors.
Protocols for metabolism assays
Add to cart Bulk requestFor research use only. Order now, ship in 3 days
Synonyms | TOS |
Sample type | cell, tissue, serum and other liquid samples |
Sensitivity | 2.5 μmol H2O2 Equiv./L |
Detection range | 2.5-100 μmol H2O2 Equiv./L |
Detection method | Colorimetric method |
Assay type | Quantitative |
Assay time | 30 min |
Precision | Average inter-assay CV: 3.500%Average intra-assay CV: 2.300% |
Other instruments required | Micropipettor, 37℃ incubator. |
Other reagents required | Normal saline (0.9% NaCl), PBS (0.01 M, pH 7.4) |
Storage | 2-8℃ |
Valid period | 12 months |
Different subscript letters indicate significant differences among the groups. (P<0.05)
X Zhao et al investigate the function of quercetin for reducing ethanol-induced hepatocyte pyroptosis. Total oxidants status (TOS) of human L02 cell was determined using TOS colorimetric assay kit (E-BC-K802-M).
It is recommended to take 2~3 samples with expected large difference to do pre-experiment before formal experiment and dilute the sample according to the result of the pre-experiment and the detection range (2.5-100 μmol H2O2 Equiv./L).
The recommended dilution factor for different samples is as follows (for reference only):
Sample type |
Dilution factor |
1 |
|
Porcine serum |
1 |
Horse serum |
1 |
Cynomolgus macaques serum |
1 |
10% Rat liver tissue homogenate |
1 |
10% Rat kidney tissue homogenate |
1 |
10% Rat lung tissue homogenate |
1 |
10% Rat spleen tissue homogenate |
1 |
0.612×10^6 Molt-4 cells |
1 |
Note: The diluent is normal saline (0.9% NaCl) or PBS (0.01 M, pH 7.4).
DOI: 10.1002/jbt.23083 |
|
PMID: 35587103 |
Sample: Hek-293 Cell |
Sample: Kidney |
Sample: Sh-Sy5Y Cell |
DOI: 10.1155/2022/4591134 |
|
Sample: L02 Cell |
S***tSubmitted [ Sep 27 2024 ]
Asked: Hello, I purchased a Total Oxidant Status (TOS) kit from your company. I have performed the analyzes but I cannot make the calculations. Can you help me with this?
Reply
adminSubmitted [ Sep 27 2024 ]
Answered: Dear Sir, We have replied 3 times for your questions, while all of our mail were retruned back. Can you contact me through cathy@elabscience.com with another mail address? Regards, Cathy
S***tSubmitted [ Sep 23 2024 ]
Asked: Hello, I purchased a total oxidant status (TOS) kit from your company and did the analyzes, but I need a ready-made excel formula to get the result. I don\'t know how to do this, can you help me?
Reply
adminSubmitted [ Sep 23 2024 ]
Answered: Dear Samet ÖZ, This is Cathy Mao who is taking care of Turkey market at the moment. We received your question about excel formula to calculate the result of Total Oxidant Status (TOS) Colorimetric Assay Kit, while the mail I sent to you was returned for times, can you offer another alternative mail address? Regards,
T***kSubmitted [ Sep 06 2024 ]
Asked: Is usable with plasma? and with which anticoagulant?
Reply
A*nSubmitted [ Sep 06 2024 ]
Answered:
A******aSubmitted [ Sep 06 2024 ]
Answered: 1. E-BC-K802-M kit, our laboratory verified that sheep plasma can be detected, TOS is 9.47μmol H2O2 Equiv./L. You may refer to it. However, there are differences between different samples. Theoretically, the TOS in plasma is higher than the kit sensitivity (2.5 μmol H2O2 Equiv./L), which can be detected. It is recommended that you select 2-3 samples for pre-experiment before the formal experiment. 2. Collect plasma samples and recommend heparin for anticoagulant.
B********eSubmitted [ Aug 17 2023 ]
Asked: We preapered the standardı solution using the normal saline however our sample and standards shows different colours(blue and purple). Is it a normal? Normally, the sample colours have to be range of the standard colours.
Reply
adminSubmitted [ Aug 17 2023 ]
Answered:
adminSubmitted [ Aug 17 2023 ]
Answered: This is a normal phenomenon, the higher concentration in the standard solution is purple, and the color of the sample is related to the TOS content in the sample, which may be blue or purple.
D**************nSubmitted [ Jul 07 2023 ]
Asked: What is the cost in Indian rupees?
Reply
adminSubmitted [ Jul 07 2023 ]
Answered: Hello Dr seema chawhan,thanks for your support.We will reply you by E-mail later.
E*oSubmitted [ Nov 24 2022 ]
Asked: Hello, what is the normal range of this kit?
Reply
adminSubmitted [ Nov 24 2022 ]
Answered: Hi Eco, The normal range for E-BC-K802-M of human serum is 33.92μmol H2O2 Equiv./L, rat serum is 97.62μmol H2O2 Equiv./L, and for mouse is 61.04μmol H2O2 Equiv./L, just for reference. If any further questions, pls feel free to contact us.
C*****BSubmitted [ Oct 27 2022 ]
Asked: hi, I\'m trying to see the wavelength through Elisa, do you have the necessary equipment for additional experiments?
Reply
adminSubmitted [ Oct 27 2022 ]
Answered: Hi Chae SB, For Instruments, Microplatereader(580-590 nm.optimum wavelength: 590nm). Micropipettor37℃ incubator. Best regards.
C*****BSubmitted [ Oct 27 2022 ]
Asked: Hi, I\'m trying to see the wavelength through Elisa, do you have the necessary equipment for additional experiments?
Reply
adminSubmitted [ Oct 27 2022 ]
Answered: Hi Chae SB, For Instruments, Microplatereader(580-590 nm.optimum wavelength: 590nm). Micropipettor37℃ incubator. Best regards.
M*****aSubmitted [ Sep 23 2022 ]
Asked: What chromogen is used in TOS kit?
Reply
adminSubmitted [ Sep 23 2022 ]
Answered: The chromogen is xylenol orange.
M*****aSubmitted [ Sep 06 2022 ]
Asked: Hi, I would like to confirm with you that can E-BC-K802-M be used for rat samples?
Reply
adminSubmitted [ Sep 06 2022 ]
Answered: Yes, of course. The kit can be used for the determination of total oxidant status (TOS) in animal tissue, serum and plasma samples