Current Position:Home>>Hot>>Immunology Related Reagents>>WB Reagents>>WB Detection Kit>> Super Excellent Chemiluminescent Substrate (ECL)Detection Kit
Catalog number:E-IR-R308
Lead Time:Order now, ship in 3 daysWelcome to order from local distributors.
Add to cart Compare Bulk request ManualIntroduction
Elabscience ® Super Excellent Chemiluminescent Substrate(ECL)Detection Kit is a horseradish peroxidase (HRP) substrate, which can be used to detect horseradish peroxidase (HRP) labeled proteins or nucleic acids, analyze protein content by Western blot or ELISA, and is compatible with film and digital development system.
The special ingredients contained in this product can effectively reduce non-specific luminescence and background luminescence, even if exposed for a long time, the background is still extremely low.
The signal of this product decays slowly, and the luminescence is not significantly weakened after 30 min, and the luminous intensity can still reach about 70% of the highest luminous intensity after 120 min.
Components
Cat.
Products
50
mL
100
mL
500
mL
Storage
E-IR-R308A
Super
ECL Substrate A
25
mL
50
mL
250
mL
2~8°C
E-IR-R308B
Super
ECL Substrate B
25
mL
50
mL
250
mL
2~8°C
Instructions
1. Western Blot
1) Follow the step of Western Blotting to block the membrane and incubate the primary/secondary antibody.
2) Wash the membrane with TBST for 3 times, 5 min each time.
3) Prepare ECL Working Solution by mixing equal parts of the ECL Substrate A and ECL Substrate B.
Note: Prepare the working solution before use, and change the pipette tips during the suction process.
4) Take an appropriate amount of mixed ECL Working Solution and add it to the membrane.
5) Adjust the exposure time according to the intensity of the luminous intensity
2. ELISA
1) Prepare Working Solution by mixing equal parts of the ECL Substrate A and ECL Substrate B.
Note: Prepare the working solution before use, and change the pipette tips during the suction process.
2) Add 50~200 μL mixed ECL Working Solution to each well into the microtiter plate.
3) Detection within 10~60 min, better within 40~50 min.
Storage
Store at 2~8°C for 12 months.
Cautions
1. Before using this product, the imprinting film must be thoroughly washed, otherwise it may cause the background to rise.
2. ECL Substrate A and ECL Substrate B must be prepared before use, and change the pipette tips during the suction process.
3. Do not expose ECL working solution to sunlight or strong light, otherwise it will cause its inactivation, and laboratory light will have little effect on the working solution.
4. NaN3 inhibits HRP activity, NaN3 should be avoided during the experiment.